PURE-AIR PA-DE3000 Explosion-Proof Dust Collector
SKU PA-DE3000 · On request
- 3000 m³/h airflow
- Up to 3000 Pa negative pressure
- Explosion-proof construction
- PPS standard control
Industrial fume extraction unit, 3000 m³/h at up to 3000 Pa. Aluminium, magnesium-aluminium alloy, titanium and other flammable or explosive dusts. PPS standard control.
Request a quote- Laser cutting
- CNC cutting
- Metal
- Explosion-proof
- Aluminium & magnesium
About this machine
The PA-DE3000 is an explosion-proof dust collector for the metals that make ordinary extraction dangerous: aluminium, magnesium-aluminium alloy and titanium. Their dust is combustible, and a conventional collector concentrates exactly the fuel and the ignition sources needed for a deflagration. The PA-DE3000 uses antistatic, flame retardant cartridges in explosion-proof construction, cleaned automatically by pulse jet. 3000 m³/h at 3000 Pa.
Filtration
- Antistatic and flame retardant PTFE cartridge bank with automatic pulse-jet cleaning
- Explosion-proof construction throughout
- Treated activated carbon available as an option
Key specifications
- Airflow: 3000 m³/h
- Maximum negative pressure: 3000 Pa
- Rated power: 3.0 kW
- Power supply: 220 V / 380 V / 415 V / 440 V, 3 ph, 50/60 Hz
- Noise level: below 73 dBA at 1 m
- Dimensions (W x D x H): 814 x 845 x 1985 mm
- Net weight: 250 kg
- Inlet: 200 mm
- Cabinet: Powder coated mild steel / brushed stainless steel
Recommended for
- Metal laser cutting tables with a bed of 100x160 cm
- Plasma and waterjet cutting cells
- Robotic welding and laser cladding cells
- Large CNC metal machining enclosures
Standard version (PPS)
This is the standard version, without the intelligent control package. From 15 September 2026 PURE-AIR supplies these units with a colour LCD touch screen and an upgraded control system. If the intelligent functions matter - real airflow readout, filter warnings, automatic compensation, RS-485 linkage - choose the i version of the same model.
When this is mandatory, not optional
PURE-AIR is explicit: if the process cuts flammable metals such as aluminium-magnesium or titanium alloy, or if flammable gases are present in the workshop, an explosion-proof model must be used. A standard collector is not an acceptable substitute.
Installation
Same as the standard industrial units, plus the explosion-proof requirements: check the sealing of the explosion-proof joints regularly, keep the earthing resistance at or below 4 ohm, empty the dust hopper often - accumulated flammable dust is the hazard - and never fit non-original accessories to an explosion-proof unit.
Technical specifications
- Phase
- 3-phase
- Airflow
- 3000 m³/h
- Inlet size
- 200 mm
- Net weight
- 250 kg
- Pre-filter
- Antistatic and flame retardant PTFE cartridge bank with automatic pulse-jet cleaning
- Main filter
- Cartridge bank with automatic pulse-jet cleaning
- Noise level
- 73 dB(A) max.
- Rated power
- 3 kW
- Power supply
- 220 V / 380 V / 415 V / 440 V, 3 ph, 50/60 Hz
- Control system
- PPS standard control
- Explosion-proof
- Yes
- Activated carbon
- Optional - treated activated carbon
- Cabinet construction
- Powder coated mild steel / brushed stainless steel
- Dimensions (W×D×H)
- 814 x 845 x 1985 mm
- Max. negative pressure
- 3000 Pa
Application details
Recommended for
Metal laser cutting tables with a bed of 100x160 cm; Plasma and waterjet cutting cells; Robotic welding and laser cladding cells; Large CNC metal machining enclosures
Materials
Aluminium, magnesium-aluminium alloy, titanium and other flammable or explosive dusts
Typical working format
100x160 cm
Control system
PPS - Pure-Air Purification System (standard control). From 15.09.2026 supplied with a colour LCD touch screen and an upgraded control system.
Installation
Same as the standard industrial units, plus the explosion-proof requirements: check the sealing of the explosion-proof joints regularly, keep the earthing resistance at or below 4 ohm, empty the dust hopper often - accumulated flammable dust is the hazard - and never fit non-original accessories to an explosion-proof unit.
Series
DE